ODI Laser Products
vaginal tightening Fractional Co2 Laser
vaginal tightening Fractional Co2 Laser vaginal tightening Fractional Co2 Laser vaginal tightening Fractional Co2 Laser

Fractional Co2 Laser Equipment Skin Resurfacing

  • item no.:

    LC10
  • Certificate:

    Medical CE, ISO13485
  • Weight:

    50kg 50kg
  • Dimension:

    114*54*99cm 114*54*99cm
  • Pulse Width:

    0.4~4ms 0.4~4ms
  • Power:

    300w 300w
  • Working Mode:

    Fractional scan, ordinary, normal, virginal Fractional scan, ordinary, normal, virginal
  • Wavelength:

    10.6μm 10.6μm
  • Laser Type:

    Fractional CO2 Laser Fractional CO2 Laser
  • Function:

    Acne Treatment, Dark Circles, Pigment Removal, Pigmentation Correctors, Pore Remover, Skin Rejuvenation, Skin Tightening, Whitening, Wrinkle Remover Acne Treatment, Dark Circles, Pigment Removal, Pigmentation Correctors, Pore Remover, Skin Rejuvenation, Skin Tightening, Whitening, Wrinkle Remover
contact now
description
skin resurfacing Fractional Co2 Laser Equipment

Fractional CO2 Laser System

Fractional co2 laser skin resurfacing machine using scanning lattice mode to emit laser, to form a burning areas consisted of lattice and interval of laser action in the epidermis, each laser action point is composed of one single or several high-energy laser pulses, it can penetrate to the dermis directly, the wrinkles or scar tissue gasify instantaneously to stimulate the regeneration of collagen, and then start the tissue repairing, collagen rearrangement and a series of skin reactions. Collagen fibers shrink under the action of laser, the skin becomes tightening and lustrous.

laser resurfacing machine video
Technical Parameters of Co2 laser machine for vaginal tightening
Laser Source Fractional co2 laser
Wavelength 10.6µ m
Machine power 300w
Laser System 0~30w
Light system Korea imported 7 joint-arm
Laser tube Glass tube (RF Tube Customized)
Modes Fractional scan & ordinary & Gynaecology & virginal
Scan Graphics 6
Scan mode 4
Dots quantity Max400
Pulse width 0.4~4 ms
Cooling water+air
Beam divergence angle 0.4 mrad
Display 8 inch LCD color touch screen
Material ABS
Treatment tips 6 types of treatment tips
Application skin resurfacing, acne treatment, scar removal, vaginal tightening etc
Parameter of Korea imported 7 joint-arm
best fractional co2 laser machine
Product Name CO2 Torsion spring Arm
Color Metallic Silver & Rich Gold
Joint 7 Joints, 360 free rotation
Delivery Length abount 1100mm
Clear Aperture 10.8mm
Power 30W/cm2
Place of Origin Korea
Accessories F-50/F-10 Surgical Handpiece, Aiming Set.
Packing Size 905mm x 305mm x 160mm
Quality comes from details
laser resurfacing machine Unique Wireless Padel

Unique Wireless Padel

Innovative wireless technology,
high-end designed appearance,
precise inside structure, easy to
move, more simple operation


laser skin resurfacing machine Korea Imported Arm

Korea Imported Arm

Korea imported 7 joint
articulated arm, easy operation
and emitting the laser energy
accurately, greatly reducec the energy loss


fractional co2 laser equipment Six Treatment Heads

Six Treatment Heads

High quality 6 types of
treatment heads offering
wide range of applications

Treatment advantages of fractional co2 laser equipment
Minimal invasive, painless procedure
Correct wavelength and perfect pulse of maximum precision CO2 laser
Deliver the CO2 laser energy fast and efficient to split into micro pixels
Improve quality of life with the lasting benefits of skin resurfacing
Safe, remarkably effective and no downtime
The energy is stable, safe and effective with 7-joint arm imported from Korea.
Each machine has stable structure inside with our mature technology.
3-5 years long life span for the glass tube, RF tube customized available.
Cooling system including copper radiator, water pump and customized fan with shaft
Application
co2 fractional laser machine Application

Whole body wrinkles removal(brow veins, glabella veins, neck veins, pregnancy veins etc)

Skin tightening and face lifting

Treatment for age spots and blemishes, acne and speckle, blain acne, scabby acne, allergic acne, papilla acne etc, improve the appearance of lipoidic skin and acne pit

Recover skin burning by sun and remove scars caused by acne or surgery

Remove skin excrescence, such as wart etc

Vagubak health treatment such as vaginal tightening and rejuvenation, mild vaginitis treatment, improve incontinence etc

Spare parts
co2 laser equipment Articulated arm

Articulated arm

co2 laser skin resurfacing machine Weight balance

Weight balance

skin resurfacing machine Array lens

Anti-scratch plate

best fractional co2 laser machine Array lens

Array lens

laser resurfacing machine Air pipe

Air pipe

laser skin resurfacing machine Wireless pedal

Wireless pedal

fractional co2 laser equipment Screwdriver & keys

Screwdriver & keys

co2 fractional laser machine Power line

Power line

co2 laser equipment Blinder & protective glasses

Blinder & protective glasses

co2 laser skin resurfacing machine Fractional mode tip and lens

Fractional mode tip and lens

skin resurfacing machine Gynec & vulval mode lens

Gynec & vulval mode lens

best fractional co2 laser machine Normal node tips

Normal node tips

laser resurfacing machine Gynecology mode tips Vulval mode tips

Gynecology mode tips Vulval mode tips

laser skin resurfacing machine Vulval mode tips

Vulval mode tips

Test Before Turning On
Power supply Please check if power cable connected well.
Array lens  Check if the array lens is installed to the machine.
Weight balance Confirm the weight balance is installed well.
Articulated arm Confirm the articulated arm is tightened.
Emergency button Confirm the emergency stop has popped up.(rotate 90°clockwise)
Machine Introduction
fractional co2 laser equipment Machine Introduction
  • ①.Articulated arm.
  • ②.Array lens.
  • ③.Weight balance,Articulated arm connector.
  • ④.Screen
  • ⑤.Emergency stop.
  • ⑥.Key switch.
  • ⑦.Array lens connector.
  • ⑧.Pedal connector.
  • ⑨.Powerline connector,Power switch.
Screen Introduction
co2 fractional laser machine Screen Introduction
  • ①.Click to Fractional mode interface.
  • ②.Click to Normal mode interface.
  • ③.Click to Gynec mode interface.
  • ④.Click to Valval mode interface.
  • ⑤.Language setting and guiding laser setting.
Fractional mode interface
co2 laser equipment Fractional mode interface
  • ①②③.means different laser shapes(triangle, square, round).
  • ④⑤⑥⑦. can adjust the size of the laser shape.
  • ⑧.can preview the shape and size of the laser.
  • ⑨⑩⑪.means the laser will come out in different ways.
  • ⑫.laser energy from 4-400mJ.
  • ⑬.means distance between the laser dots from 0.1-2.6mm.
  • ⑭.means the repeating time of laser from 1-20 times.
  • ⑮.can save 5 sets of different parameter.
  • ⑯.can turn back to the main interface.
  • ⑰.is to set the machine ready.
  • ⑱.is to set the machine standby.
Normal Mode interface
co2 laser skin resurfacing machine Fractional mode interface
  • ①.Laser will come out spot by spot.
  • ②.Laser will come out continuously.
  • ③.Laser will come out in pulse way.
  • ④.Laser energy from 1-30W.
  • ⑤.Laser duration from 0.1-100ms.
  • ⑥.Pulse width from 0.1-100.
  • ⑦.Interval from 0.1-100ms.
  • ⑧.To set the machine standby.
  • ⑨.To set the machine ready.
  • ⑩.Go back to last interface.
Gynec mode interface
skin resurfacing machine Gynec mode interface
  • ①②.means different laser shapes(square, round).
  • ③④⑤⑥.can adjust the size of the laser shape.
  • ⑦.can preview the shape and size of the laser.
  • ⑧⑨⑩.means the laser will come out in different ways.
  • ⑪.laser energy from 4-400mJ.
  • ⑫.means how many points will come out in one shot.
  • ⑬.means the points will be transferred into different rows.
  • ⑭.means how many times will be repeating.
  • ⑮.is to set the machine standby.
  • ⑯.is to set the machine ready.
  • ⑰.can go to the main interface.
Vulval mode interface
best fractional co2 laser machine Vulval mode interface
  • ①②.means different laser shapes(triangle, square, round).
  • ③④⑤⑥.can adjust the size of the laser shape.
  • ⑦.can preview the shape and size of the laser.
  • ⑧⑨⑩.means the laser will come out in different ways.
  • ⑪.laser energy from 4-400mJ.
  • ⑫.means distance between the laser dots from 0.1-2.6mm.
  • ⑬.means the repeating time of laser from 1-20 times.
  • ⑭⑮.is to set the machine standby&ready.
  • ⑯.is to go back to the last interface.


Parameter For Reference
Fractional mode Mode Energy/mJ Distance/mm Time/th / Treatment interval
Treatment course
Scar Normal 120~180 0.6-0.9 1 /
1-2/months 5-8/times
Pores shrinking Normal 80~120 0.8-1.0 1 / 1-2/months 3-5/times
Stretch marks Normal
100~150 0.7-1.0 1 / 1-2/months 6-8/times
Acne scars Normal 100~150 0.6-0.9 1 / 1-2/months 4-6/times
Skin rejuvenation Normal 80~120 0.7~1.0 1 / 1-2/months 2-4/times
Normal mode Mode Power/w Duration/ms Pulse Width/ms Interval/ms Treatment interval Treatment course
Pigment Single-time 20~23 1.5-3.0 / / 1/month 2-3/times
Dispelling nevus Impulse 7~8 / 0.4 10~20 1/month 1-2/times
Wart Impulse 20~23 1.5-3.0 / / 1/month 1-3/times
Fat particles Single-time 18~20 1.5-3.0 / / 1/month 1/time
Gynec mode Mode Energy/mJ Points Rows Times/th Treatment interval Treatment course
Vaginal tightening Normal 150-200 30-45 3-5 1 1-2months 3-5/times
Vulval mode Mode Energy/mJ Distance/mm Times/th / Treatment interval Treatment course
Pink areola Normal 50~80 0.8~1.0 1 / 1-2/month 3-5/times
Vulva Pink Normal 60~90 0.8~1.0 1 / 1-2/month 4-6/times
Fractional CO2 Laser Treatment Before and After

laser resurfacing machine Fractional CO2 Laser Treatment Before and After


related tags :

co2 laser resurfacing machine best fractional co2 laser machine laser resurfacing machine laser skin resurfacing machine fractional co2 laser equipment co2 fractional laser machine co2 laser equipment co2 laser skin resurfacing machine skin resurfacing machine

related tags :

inquiry

subject : Fractional Co2 Laser Equipment Skin Resurfacing

online service

service

online service